Contents: Early models ⇓ Late model years ⇓
Early models
In these vehicles, the ignition coil is mounted in the distributor.
Ignition coil installation location in the distributor
The resistance of the primary winding of the ignition coil is measured on engines with a fuel injection device between terminals I and 2. Resistance of the primary winding: 0.9±1.2 Ohm; secondary winding resistance 20±29 kOhm.
In some vehicles, the resistance of the primary winding of ignition coil 1 is measured between contacts 3 and 2 of the connector, coil 2 between contacts 3 and 1 of the connector. Coil 1 serves cylinders 1 and 4, and coil 2 - cylinders 2 and 3.

Attention: The ignition coil is designed for a specific ignition system and can only be replaced with a coil of the same design and with the same index. Be careful.
Late model years
When measuring the resistance of the primary winding of the ignition coil, measure the resistance value between terminals 11 and 12 of the ignition distributor connector.

Nominal value 0.5-0.7 Ohm.
When measuring the resistance of the secondary winding of the ignition coil, measure the resistance value between the high-voltage terminal and terminals 11 and 12 of the connector. The nominal value is 21-30 kOhm.