2. Measure the resistance of the secondary winding. Measure between the high voltage terminal: for the 1st and 4th, 2nd and 3rd cylinders (2.0 l engine), for the 3rd and 6th cylinders, 2nd and 5th, 1st and 4th. The normal resistance value is 8.8±15% kOhm (2.0 l engine), 13.3±15% kOhm (2.7 l engine).
![]() |
![]() |