Withdrawal
1. Disconnect a wire from the negative plug of joint stock bank.
2. Remove the right facing of the floor console (1).
3. Disconnect the sensor connector (2).
4. Remove the retainer (3) and remove the sensor (4) from the heater.
Installation
5. Installation is carried out in the reverse order of removal.
Examination
6. Turn on the ignition.
7. Measure the resistance of the sensor with an ohmmeter. If the measured value is out of specification, replace the sensor.
Coolant temperature,°С | Resistance, kOhm±3% | Voltage, V±3% |
-10 | 55,85 | 4,24 |
0 | 32,91 | 3,83 |
10 | 19,99 | 3,33 |
20 | 12,51 | 2,78 |
30 | 8,047 | 2,23 |
40 | 5,311 | 1,73 |
50 | 3,588 | 1,32 |
60 | 2,476 | 0,99 |
70 | 1,742 | 0,74 |
80 | 1,246 | 0,55 |