Removal
1. Disconnect the wire from the negative terminal of the battery.
2. Remove the right floor console trim (1).

3. Disconnect the sensor connector (2).

4. Remove the retainer (3) and remove the sensor (4) from the heater.

Installation
5. Installation is carried out in the reverse order of removal.
Examination
6. Turn on the ignition.
7. Use an ohmmeter to measure the sensor resistance. If the measured value does not match the nominal value, replace the sensor.

| Coolant temperature, °C | Resistance, kOhm ±3% | Voltage, in ±3% |
| -10 | 55,85 | 4,24 |
| 0 | 32,91 | 3,83 |
| 10 | 19,99 | 3,33 |
| 20 | 12,51 | 2,78 |
| 30 | 8,047 | 2,23 |
| 40 | 5,311 | 1,73 |
| 50 | 3,588 | 1,32 |
| 60 | 2,476 | 0,99 |
| 70 | 1,742 | 0,74 |
| 80 | 1,246 | 0,55 |