Withdrawal
Drain the coolant below the sensor installation level.
Disconnect the battery and temperature sensor connector
Pic. 2.293. coolant temperature sensor
Remove the sensor (pic. 2.293).
Installation
Apply the recommended sealant to the sensor threads. Tighten the sensor to the specified torque.
Sealant: Three Bond No. 1324N or Loctite 262.
The moment of an inhaling of the gauge of temperature of a cooling liquid: 20–40 Н·м.
Connect the temperature sensor connector.
Connect the battery.
Fill the cooling system.