Withdrawal
1. Turn away bolts of fastening of a pulley of the pump of a cooling liquid.
2. Turn away a nut of a support of the generator.
3. Turn away a lock bolt of the generator and remove a belt.
4. Turn away bolts of fastening of a pulley of the pump of a cooling liquid and remove a pulley of the pump of a cooling liquid.
Tightening torques:
- Nut A of the generator support - 20-25 Nm
- Locking bolt B generator - 15-22 Nm
Examination
Carry out the following checks and replace the belt if necessary.
1. Check the belt surface for damage, peeling or cracks.
2. Make sure there is no oil or grease on the belt surface.
3. Check the belt for wear and hardened areas.
4. Check for cracks or damage on pulley surfaces.
Installation
1. Install the water pump pulley on the pulley hub and tighten the pulley bolts securely.
2. After installing the belt, adjust its tension.