Removal
1. Remove the engine cover and disconnect the vacuum hose (B). Remove the valve (A) from the cylinder head cover.

Examination
2. Insert a thin rod (A) into the valve (B) from the threaded connection side and check the plunger movement. If the plunger does not move, clean or replace the valve.

Installation
3. Installation is carried out in reverse order.