Withdrawal
1. Drain the coolant to a level below the sensor.
2. Disconnect a wire from the negative plug of the storage battery and a socket from the gauge.
3. Remove the coolant temperature sensor.
Examination
1. Heat the coolant temperature sensor by immersing it in hot coolant.
2. Measure the resistance of the sensor. Resistance: 2.31-2.59 ohms at 20°C.
Installation
1. Apply sealant to the threads of the coolant temperature sensor and screw in the sensor, tightening it to the required torque. Sealant: Threebond #1324N or LOCTITE 262 Torque: 20-40 Nm.
2. Connect the electrical connector to the sensor.
3. Connect a wire to the negative plug of the storage battery.
4. Fill the cooling system with the required amount of the required coolant.