Checking the technical condition
1. Turn off the ignition.
2. Disconnect the purge control solenoid connector (PCSV).
3. Measure the resistance between terminals 1 and 2 of the PCSV.
4. Check that the resistance is within specification.
Withdrawal
1. Turn the ignition key to the OFF position and disconnect the negative (-) battery wire.
2. Disconnect the connector (A) purge control solenoid valve.
3. Disconnect the steam lines (IN) from the purge control solenoid valve.
4. Remove the bolt (WITH) bracket and then remove the valve from the smoothing tank.
Installation
Attention.
- Tighten the component mounting bolts to the correct torque.
- Be careful not to drop the component. In the event of a drop, the component must be carefully checked before installation.
- Do not allow foreign material to enter inside the valve.
- Installation is carried out in the reverse order of removal.
Note: Torque: Purge control solenoid valve bracket bolt (PCSV): 9.8 - 11.8 Nm.