Checking the technical condition
1. Turn off the ignition.
2. Disconnect the oil control valve connector (OCV).
3. Measure the resistance between terminals 1 and 2 of the valve.
4. Check that the resistance is within specification.
Withdrawal
1. Turn the ignition key to the OFF position and disconnect the negative (-) battery wire.
2. Disconnect the connector (A) oil control valve.
3. Remove the bolt (IN) fasteners and remove the valve.
[Bank 1 / intake valves]
[Bank 1 / exhaust valves]
Installation
Attention.
- Tighten the component mounting bolts to the correct torque.
- Be careful not to drop the component. In the event of a drop, the component must be carefully checked before installation.
- Lubricate the valve seal with engine oil.
- Installation is carried out in the reverse order of removal.
Note: Tightening torque: Oil control valve bolt: 9.8 - 11.8 Nm.