2. Disconnect the electrical wiring connector.
3. Connect the vacuum pump to the nipple to which the vacuum hose marked with red tape was connected.
4. Turn on the vacuum supply and check with voltage applied to the valve and with voltage disconnected.
| Battery voltage | Normal condition |
| Served | The vacuum is weakening |
| Not served | The vacuum remains |
5. Measure the resistance between the terminals of the solenoid valve.
- EVAP valve. Coil resistance - 26 Ohm (at 20°C)