Withdrawal
1. Disconnect the electrical connector from the air flow sensor.
2. Remove the air inlet connected to the air filter.
3. Turn out three bolts of fastening of an arm of the air filter.
4. Remove the air filter.
5. Remove the air flow sensor from the air tube.
Warning! Do not pull on the air flow sensor wires.
Examination
1. Check the air filter housing and cover for deformation, corrosion or damage.
2. Check the air duct for damage.
3. Check the air filter element for excessive contamination, damage, or oil ingress. To clean the filter element, use compressed air from the inside of the filter element. If necessary, replace the air filter element.
Installation
Installation is carried out in the reverse order of removal.