Examination
1. Check continuity between pins 5 () and 1 (–) relay.
Relay winding (between pins 5 and 1) | Conductivity |
Winding included | No |
Winding off | Yes |
2. If the relay is defective, replace it.
Relay winding (between pins 5 and 3) | Conductivity |
Winding off | No |
Winding included | Yes |