Replacement
1. Drain the refrigerant from the system.
2. Replace defective tube or hose.
Evaporator temperature sensor
Attention. Close open fittings immediately to prevent moisture or dirt from entering the system.
3. Tighten the connection bolt or nut to the required torque.
Attention. Do not exceed the specified values of the moments in the connections.
Note:
Required torques: Condenser - drain hose and condenser - liquid pipe: 4.9 - 5.9 Nm.
Compressor - drain hose and compressor - suction hose: 4.9 - 5.9 Nm.
Expansion valve - evaporator: 11.8 - 14.7 Nm.
4. Remove air from the system and charge it with refrigerant.
Note: Nominal volume: 510±25g.
5. Check the system for refrigerant leaks using a leak detector.
6. Check up functioning of system of central air.