2. Remove the expansion tank of the cooling system.
3. Remove bolt A and remove bracket B.
4. Loosen bolts A and disconnect the pressure pipe. After disconnection, secure the pipeline to prevent contamination.
5. Unscrew bolts A, remove capacitor B. Remove carefully to avoid damage to the capacitor or radiator.
6. Reassemble in reverse order, taking into account the following:
- when installing a new condenser, it is necessary to add refrigerant and oil to the system;
- replace all seals with new ones;
- lubricate with a small amount of oil before installing the seal;
- use seals for R-134a refrigerant;
- make sure that the installation of a new capacitor is reliable;
- charge the system with refrigerant and test.