Damper drive right
Supply voltage 12 V, response time 4 sec, opening current 0.1 A, closing current 0.55 A.
Replacement
1. Disconnect connector A from drive C. Loosen screws B, remove drive C.
2. Install in reverse order. After installation, check the drive for smooth operation.
Damper drive left
Supply voltage 12 V, response time 4 sec, opening current 0.1 A, closing current 0.55 A.
Replacement
1. Disconnect connector A from drive C. Loosen screws B, remove drive C.
2. Install in reverse order. After installation, check the drive for smooth operation.