Withdrawal
1. Remove the piping attached to the air filter.
2. Disconnect the wiring for the intake air temperature sensor.
3. Disconnect the air inlet hose from the air filter side.
4. Remove the air filter cover and filter element.
5. Remove the air filter mounting bolts and the filter itself.
Check and installation
1. Check the air filter housing, cover and filter element for corrosion and damage.
2. Check piping.
3. Check the resonator for deformation and damage.
4. Check the filter element for clogging, contamination and damage.
If it is slightly clogged, remove dust and dirt by blowing.
5. Installation is carried out in the reverse order of removal.