Checking the technical condition
1. Turn off the ignition.
2. Disconnect the EGR cooler bypass solenoid connector.
3. Measure the resistance between terminals 1 and 2 of the valve.
4. Check that the resistance is within specification.
Withdrawal
1. Turn the ignition key to position «OFF» and disconnect the negative (-) battery wire.
2. Disconnect the connector (A) bypass solenoid valve of the cooler of the exhaust gas recirculation system.
3. Disconnect the vacuum hose (IN) from the bypass solenoid valve of the cooler of the exhaust gas recirculation system.
4. Turn away a fixing bolt and remove the valve (WITH).
Installation
Attention.
- Tighten the component mounting bolts to the correct torque.
- Be careful not to drop the component. In the event of a drop, the component must be carefully checked before installation.
Installation is carried out in the reverse order of removal.
Note: Tightening torque: EGR cooler bypass solenoid valve bolt: 7.8 - 11.8 Nm.