1. Loosen the bolts (A, B) mounting of longitudinal and transverse levers.
2. Jack up the subframe (IN), then loosen the bolts (A) fasteners and remove the subframe assembly.
3. Loosen the bolts (A) mounting brackets (IN) transverse levers.
4. Remove the transverse levers.
5. To wrap bolts of fastening of arms of cross-section levers. Tightening torque 160-180 Nm.
6. Make sure that the alignment mark (IN) on a stretcher (A) directed in the direction of the vehicle.
7. To wrap, without tightening, bolts of fastening of cross-section levers. Then tighten the bolts with the vehicle on the ground. Tightening torque 16Y -180 Nm.