2. Disconnect the return hose from the booster hydraulic reservoir and install a plug in the hole.
3. Connect the flexible hose to the return hose and drain the working fluid into a suitable container.
4. Disconnect high voltage spark plug wires from ignition coils. To completely drain the working fluid, rotate the engine crankshaft with several short-term starter starts, constantly turning the steering wheel from one extreme position to another. Then connect the high voltage wires to the ignition coils.
5. Connect the return hose securely and fill the hydraulic reservoir with the recommended fluid.
- Working fluid - PSF-3
- Filling capacity - 0.9 l
6. Start the engine. Check for fluid leaks.
7. Stop the engine.