Withdrawal
1. Discharge the air conditioning system from the refrigerant, disconnect the hose from the radiator and drain the coolant.
2. Turn out two bolts and remove an air inlet.
4. Disconnect the connector from the fan motor.
Examination
1. Check the condenser plates for blockages and damage.
In case of clogging, flush the condenser plates with a jet of water and blow with compressed air. Carefully straighten bent plates with a screwdriver or pliers.
2. Check the condenser fittings for signs of leakage.
Installation
Installation is carried out in the reverse order of removal.