Examination
1. Check manifold for damage or cracks.
2. Using a square and a feeler gauge, check the deformation of the surface of the cylinder head mating with the collector.
- Standard value - 0.15 mm or less
- Tolerance limit - 0.2 mm or less
3. Check the gasket for delamination or defects.