2. Remove air from the system. Start the engine and turn the steering wheel several times to raise the operating temperature of the fluid to 50°C.
3. Set the engine speed to about 1000 rpm.
4. Fully close and then fully open the tool shut-off valve and measure fluid pressure.
Oil pump pressure (norm):
- With a closed valve in the hose - 7.85 MPa
Warning. Do not keep the shut-off valve pressurized and closed for more than 10 seconds.
5. Remove tool and tighten hose.
- Tightening torque - 16-24 Nm.
6. Bleed the system to remove air.