Ignition Timing - Determined by Control Module
Identification number - 1ED0031A (MANDO) / TOO1542170 (MELCO)
Ignition coil
Primary winding resistance - 0.8±0.08 Ohm
Resistance of the secondary winding - 12.1±1.21 kOhm
Starter
Type | direct drive (with planetary gear) | Gear drive |
Voltage | 12 V | 12 V |
output power | 0.9 kW | 1.2 kW |
Characteristics without load | ||
Terminal voltage | 11.5V | 11 V |
Current consumption | Max. 60 A | Max. 90 A |
Rotation frequency | Min. 3000 rpm | Min. 6600 rpm |
Number of gear teeth | 8 | 8 |
Pinion play | 0.5-2mm | 0.5-2mm |
Spark plug
Type | For leaded gasoline | For unleaded gasoline |
NGK | BPR6ES | BPR6ES-11 |
Champion | RN9YC | RN9YC4 |
Interelectrode gap | 0.7-0.8mm | 1.0-1.1mm |
Generator
Rated Power - 12V/75A
Rotation frequency - 1000-1800 rpm
Setting the regulator - 14.4±0.3 V
Temperature compensation — -10±3 mV/°С
Type of voltage regulator - Electronic built-in
Accumulator battery
Standard | Custom | |
Type | NX100—S6MF | MF 68 Ah |
buffer mode | 80 min. | 122 min. |
Density (at 25°C) | 1,270±0,01 | 1,270±0,01 |
Energy intensity | 36 Ah | 55 Ah |
46 Ah | 68 Ah |
Tightening torque, Nm
Generator (B+) — 5-7
Starter (B+) — 10-12
Battery - 4-6
Spark plug - 20-30